Electric environments can be efficient

An energy assessment is the first step in creating an energy efficient environment, and should be done to any home or commercial space. Assessments give you an in depth look at how your space uses energy.


How It Works

You will receive a complete energy overview of your kWh consumption which be completed with metered equipment. Then after we review the data for the possibility of kWh reduction in consumption through and with clean power. We will determine where you are inefficient, and then give you quick fix solutions as well as the most cost effective options on how to make improvements. These solutions will lower your utility bills, make your space healthy, comfortable, and lower your carbon emissions.

Electrical Terminology

Today’s modern world is primarily powered by Nikola Tesla’s alternating current. In order to understand the key attributes of alternating current, there are a few terms you must familiarize yourself with. Alternating current has 10 key attributes that are commonly discussed in the equipment we use to harmonize your electricity.

1. Voltage ~ volts (V): are a unit of electrical force or potential difference that will cause a steady current of one amp to flow through a resistance of one ohm.  

Simplified ~ voltage is a measure of the electrical pressure or how hard the amps are being pushed.

The Power Perfect equipment we use stabilizes and helps maintain consistent voltage.

2. Amperage ~ amperes (A): commonly referred to as amps are a unit of electrical current or flow rate of electrons. One volt across one ohm of resistance causes a current flow of one ampere.

Simplified ~ amperage is measure of how much current or how many electrons are flowing and is therefore the flow rate of electrical energy (electricity) measured in amps.

The Power Perfect equipment we use increases average power, while improved power factor lowers amps and increases efficiency.

3. Watts ~ power (W): are a measure of power and the product of voltage and amperage and the rate of energy transfer equivalent to one ampere under the electrical pressure of one volt. One watt equals one joule per second.

Simplified ~ watts are the measure of real working power. 

4. Kilowatt-hour ~ energy (kWh): The kWh is a unit of energy 1,000 thousand watts acting over a period of 1 hour.

Simplified ~ kilowatt-hours are the measure of real working power used over time and are the standard of measure utilities use to bill for electricity.

5. Power factor ~ ratio (PF): is the ratio of actual real power being used, measured in watts, to the total power that is being drawn from a power source, expressed in volt-amps (VA).

PF = real power / apparent power.

Simplified ~ Power Factor is simply the ratio of real working power (watts) to total apparent power (volt-amps) VA. PF = W / VA

*A common misconception about electrical billing and real power is that volts x amps = watts. This is inaccurate as volts x amps = volt amps or total power. Volts x amps x power factor = watts or real power. This is why increasing power factor may not lower utility costs for residential consumers, yet frequently will for industrial consumers.*

The Power Perfect equipment we use reduces total power and therefore losses to ohms law, consistently reducing watts. 

6. Total harmonic distortion ~ ratio (THD): is the measure of the harmonic content or number of unwanted frequencies in the output waveform in addition to the primary or desired frequency (50 or 60 Hz.). Energy in these harmonic frequencies is lost and may cause excessive heating of the load.

Simplified ~ THD is the how far the real-time waveform is from ideal (60Hz of 50Hz) and how many undesired frequencies are on the wave.

The Power Perfect equipment we use is proven to lower harmonics and distortion.

7. Electromagnetic fields (EMF): Electric and magnetic fields are invisible areas of energy (also called radiation) produced by electricity, which is the movement of electrons, or current, through a wire. V/m, μT, W/m2.

The electric field is produced by voltage, which is the pressure used to push the electrons through the wire. As the voltage increases, the electric field increases in strength. Electric fields are measured in volts per meter (V/m).

The magnetic field results from the flow of current through wires or electrical devices and increases in strength as the current increases. The strength of a magnetic field decreases rapidly with increasing distance from its source. Magnetic fields are measured in micro-teslas (μT, or millionths of a tesla).

Electric fields are produced whether or not a device is turned on, whereas magnetic fields are produced only when current is flowing, which usually requires a device to be turned on.

Power lines produce magnetic fields continuously because current is always flowing through them. Electric fields are easily shielded or weakened by walls and other objects, whereas magnetic fields can pass through buildings, living things, and most other materials.

Electric and magnetic fields together are referred to as electromagnetic fields, or EMFs. The electric and magnetic forces in EMFs are caused by electromagnetic radiation.

The Power Perfect equipment we use filters consistently lower EMF’s and their subsequent radiation. 

8. Interference: any unwanted signal that’s combined with the desired signal is called interference and can come from external systems as well as from within a circuit itself. External sources include a number of sources such as power lines, RF transmitters, nearby conductors, ignition systems, or motors that turn on and off drawing sudden large currents.

Electromagnetic interference (EMI) is the noise caused by current in other, nearby conductors or cables. Radio frequency interference (RFI) is also a source of external noise caused by radiating signals from wireless systems

The Power Perfect equipment we use filters consistently lower interference and their negative effects on electronics. 

9. Ohms ~ resistance (R): Is a unit of electrical resistance of either a resistor or conductor which opposes the flow of an electric current resulting in the generation of heat in the conducting material. The measure of the resistance of a given conductor is the electromotive force needed for a unit current flow, stated in ohms.

SATIC Simplified ~ Ohms law of resistance is a measure of how much of the electrical energy being converted to heat, sound, light or mechanical work as electricity travels through the circuit.

The Power Perfect equipment we use reduces total power and therefore losses to ohms law, consistently reducing watts. 

10. Hertz ~ frequency (Hz): The number of repetitions per unit time of a complete waveform, expressed in Hertz (Hz).

SATIC Simplified ~ Frequency (Hz) is how often an event repeats itself. How many waves hit the beach in one minute is their frequency. 

The Power Perfect equipment we use saturates out at and maintains primary frequency. 

Area of Focus

Energy Audits are offered for both residential homes and commercial work places by one of our Certified and Insured Energy Auditors. Every living space and work space is unique, so measurements need to be taken at strategic points throughout the home or work place.


Individualized Report

An individualized report will be prepared as the result of each home or workplace surveyed. The report provides the knowledge needed for an energy efficient, safe and healthy environment.

  • The report will detail in plain English the results of the survey, how the monitoring results affects people, how the monitoring results affects the home or workplace

  • If an issue or issues are found we will do testing to give you options to remedy the issue

  • Recommend solutions to areas of concern that will allow for reasonable and cost-effective mitigation

  • All Energy Audits are performed by one one our trained Energy Auditors

  • Any and all electrical installations or repairs are completed by one of our licensed electricians


Customized Action Plan

An Energy Audit will explain problems that may, when corrected, save you significant amounts of money over time while helping you to live or work happier, healthier and more comfortably.

Based on the readings and your budget, we help you prioritize the solutions needed to reduce your energy costs.

Many of the recommended solutions are free. Some of them are very accessible, while some are quite costly. We will give you an honest, practical plan of action based on your situation.

  • We are all about practical, simple solutions.

  • Our best advice: don't wait.

Schedule Your Energy Audit